PartNumber | SI-9002 |
Delivery time | 2 weeks |
Price from | 373,00 € ex. VAT |
Description
Adds a high voltage differential input to your oscilloscope. The Differential probe SI-9002 extends the measurement power of oscilloscopes to power semiconductor circuits. This Differential Probe provides any general oscilloscope with a high voltage differential input.
The Differential probe SI-9002 is small and light, so it can be used in a very convenient way; just plug it into the input of, for example, the Handyscope HS5. The wide bandwidth and the high accuracy of this Differential Probe cater for a wide range of applications.
- 1:20 and 1:200 attenuation
- 14 ns rise time
- 25 MHz bandwidth
- 1000 V CAT III rating
Differential probe SI-9002 - Specification | |
---|---|
Bandwidth | DC to 25MHz (-3dB) |
1:20 or 1:200 | |
Accuracy | ±2% |
Rise Time | 14 ns |
Input Impedance | 4 MOhm 5.5 pF each side ground |
Input Voltage | |
Differential Range 1 | |
1:20 | ±140 V (DC+Peak AC) or 140 Vrms |
1:200 | ±1400 V (DC+Peak AC) or 1000 Vrms |
Common Mode Range | ±1400 V (DC+Peak AC) or 1000 Vrms |
Absolute Max. Voltage 1 | ±1400 V (DC+Peak AC) or 1000 Vrms CAT III |
Output | |
Swing (into 2k ohm load) | +/-7 V |
Offset (typical) | <+/-5 mV |
Noise (typical) | 0.7 mVrms |
Impedance (typical) | 50 Ohm (for using 1 MOhm input system oscilloscope) |
CMRR (typical) | -80 dB @ 50 Hz, -60 dB @ 20 kHz |
Ambient | |
Operating Temperature | -10 to 40 °C (14 to 104 F) |
Storage Temperature | -30 to 70 °C (-22 to 158 F) |
Operating Humidity | 25 to 85% RH |
Storage Humidity | 25 to 85% RH |
Power Requirements | Standard 4 x AA cells or regulated 9 VDC / 40mA mains adapter 2 |
Length of BNC Cable | 95 cm (37.4 inch) |
Length of Input Leads | 45 cm (17.7 inch) |
Weight (differential probe and PVC jacket) | 400 g (14.1 ounce) |
Dimensions | |
Height | 21 mm (0.8 inch) |
Length | 170 mm (6.7 inch) |
Width | 63 mm (2.5 inch) |
- Voltage limit is the lesser of the DC+Peak AC and RMS values.
-
- The supplied voltage must be less than 12V and greater than 4.4V, otherwise the differential probe could be damaged or can't be operated properly.
- Polarity is "+" inside and "-" outside. For wrong polarity, built-in circuit protects the differential probe, no danger or damage will occur.
- When the voltage of the cells become too low, the power indicator on the panel will flicker.