PartNumber | HS5 |
Delivery time | 2 weeks |
Price from | 930,00 € ex. VAT |
The new 500 MS/s 14 bit dual channel High Resolution Oscilloscope with function generator.
This powerful high speed USB oscilloscope combines fast sampling up to 500 MS/s with high resolutions of 12, 14 and 16 bit, a large memory of 64 MSamples and an extremely accurate built-in 40 MHz 14 bit Constant Data Size (CDS) arbitrary waveform generator with 24 V peak to peak output, generating true form signals.
The oscilloscope supports continuous streaming measurements up to 20 MS/s and can be synchronized with other oscilloscopes using the CMI interface to form a multi channel combined instrument with synchronized timebase. The CMI interface is available by default on the Handyscope HS5.
Optionally, the Handyscope HS5 can be delivered with SureConnect connection test and resistance measurement on each channel.
The flexibility and quality that the Handyscope HS5 offers is unparalleled by any other oscilloscope and function generator in its class.
Integration
Bohemian Technology Group s.r.o. is an official technical and technical support partner for integrating TiePie oscilloscopes into all applications. We specialize in the .NET C # implementation and can help you with less common tasks.
Download:
File |
HS5 Manual |
Acquisition system | |
---|---|
Number of input channels | 2 analog |
CH1, CH2 | BNC |
Type | Single ended |
Resolution | 8, 12, 14, 16 bit user selectable |
DC Accuracy | 0.25 % (0.1 % typical) of full scale ± 1 LSB |
Ranges | ±200 mV to ±80 V full scale |
Coupling | AC/DC |
Impedance | 1 MOhm / 25 pF ± 1 % |
Maximum voltage | 200 V (DC + AC peak < 10 kHz) |
Maximum voltage 1:10 probe | 600 V (DC + AC peak < 10 kHz) |
Bandwidth (-3dB) | at 75 % of full scale input |
Ch1 | 250 MHz |
Ch2 | 100 MHz |
AC coupling cut off frequency (-3dB) | ±1.5 Hz |
SureConnect | Optionally available (option S) |
Maximum voltage on connection | 200 V (DC + AC peak < 10 kHz) |
Resistance measurement | Optionally available (option S) |
Ranges | 100 Ohm to 2 MOhm full scale in 1-2-5 sequence |
Accuracy | 1 % of full scale |
Response time (to 95%) | < 10 µs |
Maximum sampling rate | Depending on model |
Model HS5-540 | |
8/12 bit, measuring one channel | 500 MS/s |
8/12 bit, measuring two channels | 200 MS/s |
14 bit | 100 MS/s |
16 bit | 6.25 MS/s |
Model HS5-530 | |
8/12 bit, measuring one channel | 500 MS/s |
8/12 bit, measuring two channels | 200 MS/s |
14 bit | 100 MS/s |
16 bit | 6.25 MS/s |
Model HS5-220 | |
8/12 bit, measuring one channel | 200 MS/s |
8/12 bit, measuring two channels | 100 MS/s |
14 bit | 50 MS/s |
16 bit | 3.125 MS/s |
Model HS5-110 | |
8/12 bit, measuring one channel | 100 MS/s |
8/12 bit, measuring two channels | 50 MS/s |
14 bit | 20 MS/s |
16 bit | 1.25 MS/s |
Model HS5-055 | |
8/12 bit, measuring one channel | 50 MS/s |
8/12 bit, measuring two channels | 20 MS/s |
14 bit | 10 MS/s |
16 bit | 625 kS/s |
Maximum streaming rate | Depending on Handyscope HS5 model and computer 1 |
Model HS5-540 | |
8 bit, measuring one channel | 40 MS/s |
8 bit, measuring two channels | 20 MS/s |
12/14 bit, measuring one channel | 20 MS/s |
12/14 bit, measuring two channels | 10 MS/s |
16 bit | 6.25 MS/s |
Model HS5-530 | |
8 bit, measuring one channel | 40 MS/s |
8 bit, measuring two channels | 20 MS/s |
12/14 bit, measuring one channel | 20 MS/s |
12/14 bit, measuring two channels | 10 MS/s |
16 bit | 6.25 MS/s |
Model HS5-220 | |
8 bit, measuring one channel | 20 MS/s |
8 bit, measuring two channels | 10 MS/s |
12/14 bit, measuring one channel | 10 MS/s |
12/14 bit, measuring two channels | 5 MS/s |
16 bit | 3.125 MS/s |
Model HS5-110 | |
8 bit, measuring one channel | 10 MS/s |
8 bit, measuring two channels | 5 MS/s |
12/14 bit, measuring one channel | 5 MS/s |
12/14 bit, measuring two channels | 2 MS/s |
16 bit | 1.25 MS/s |
Model HS5-055 | |
8 bit, measuring one channel | 4 MS/s |
8 bit, measuring two channels | 2 MS/s |
12/14 bit, measuring one channel | 2 MS/s |
12/14 bit, measuring two channels | 1 MS/s |
16 bit | 625 kS/s |
Sampling clock source | |
Internal | TCXO |
Accuracy | ± 0.0001 % |
Stability | ± 1 ppm over 0°C to 55°C |
Time base aging | ±1 ppm/year |
External | LVDS, on auxiliary connectors |
Input range | 10 MHz ± 1 % |
Memory | |
Standard model | 128 KiSamples per channel |
XM option | 32 MSamples per channel 64 MSamples measuring one channel |
Trigger | |
System | Digital, 2 levels |
Source | CH1, CH2, OR, digital external, generator start, generator new period, generator stop |
Trigger modes | Rising edge, falling edge, any edge, inside window, outside window, enter window, exit window, pulse width |
Level adjustment | 0 to 100 % of full scale |
Hysteresis adjustment | 0 to 100 % of full scale |
Resolution | 0.006 % (14, 16 bits) / 0.025% (12 bits) |
Pre trigger | 0 to 64 MSamples measuring 1 channel, 0 to 32 MSamples measuring 2 channels, 1 sample resolution |
Post trigger | 0 to 64 MSamples measuring 1 channel, 0 to 32 MSamples measuring 2 channels, 1 sample resolution |
Trigger hold-off | 0 to 63 MSamples, 1 sample resolution |
Trigger delay | 0 to 16 GSamples, 1 sample resolution |
Segmented trigger | Available via LibTiePie SDK |
Maximum number of segments | 1024 |
Minimum segment length | 1 sample |
Maximum segment length | 32 M / number of segments 64 M / number of segments measuring one channel |
Trigger rearm time | Sample frequency dependent, < 700 ns on highest sample frequency |
Digital external trigger | |
Input | Extension connector pins 1, 2 and 3 |
Range | 0 to 2.5 V (TTL) |
Coupling | DC |
Jitter | Depending on source and sample frequency |
Source = channel | ≤ 1 sample |
Source = external or generator | |
Sample frequency = 500 MS/s | ≤ 8 samples |
Sample frequency < 500 MS/s | ≤ 4 samples |
Sample frequency ≤ 100 MS/s | ≤ 1 sample |
- On some computers, the highest streaming rates may not be available, due to computer restrictions.
Arbitrary Waveform Generator (independent from acquisition system) | |
---|---|
Waveforms | |
Standard | Sine, square, triangle, pulse, noise, DC |
Built-in arbitrary | Exponential rise and fall, sin(x)/x, cardiac, haversine, lorentz, d-lorentz |
Signal characteristics | |
Sine | |
Frequency range | Depending on model |
Model HS5-540 | 1 µHz to 40 MHz |
Model HS5-530 | 1 µHz to 30 MHz |
Model HS5-220 | 1 µHz to 20 MHz |
Model HS5-110 | 1 µHz to 10 MHz |
Model HS5-055 | 1 µHz to 5 MHz |
Amplitude flatness | Relative to 1 kHz |
< 100 kHz | ±0.1 dB |
< 5 MHz | ±0.15 dB |
< 20 MHz | ±0.3 dB (Amplitude ≤ 11 V (22 Vpp)) |
< 30 MHz | ±0.4 dB (Amplitude ≤ 9 V (18 Vpp)) |
< 40 MHz | ±1 dB (Amplitude ≤ 7.5 V (15 Vpp)) |
Spurious (non harmonic) | |
< 100 kHz | -75 dBc |
100 kHz to 1 MHz | -70 dBc |
1 MHz to 10 MHz | -60 dBc |
10 MHz to 15 MHz | -55 dBc |
15 MHz to 20 MHz | -45 dBc |
20 MHz to 30 MHz | -35 dBc |
30 MHz to 40 MHz | -30 dBc |
Square | |
Frequency range | Depending on model |
Model HS5-540 | 1 µHz to 30 MHz, above 30 MHz not specified |
Model HS5-530 | 1 µHz to 30 MHz |
Model HS5-220 | 1 µHz to 20 MHz |
Model HS5-110 | 1 µHz to 10 MHz |
Model HS5-055 | 1 µHz to 5 MHz |
Rise/fall time | < 8 ns |
Overshoot | < 1 % |
Variable duty cycle | 0.01 % to 99.99 % |
Asymmetry | 0 % of period + 5 ns (@ 50 % Duty cycle) |
Jitter (RMS) | < 50 ps |
Triangle | |
Frequency range | Depending on model |
Model HS5-540 | 1 µHz to 30 MHz, above 30 MHz not specified |
Model HS5-530 | 1 µHz to 30 MHz |
Model HS5-220 | 1 µHz to 20 MHz |
Model HS5-110 | 1 µHz to 10 MHz |
Model HS5-055 | 1 µHz to 5 MHz |
Nonlinearity (of peak output) | < 0.01 % |
Symmetry | 0 % - 100 %, 0.1 % steps |
Pulse | |
Period | 100 ns to 1000 s |
Pulse width | 15 ns to 1000 s |
Variable edge time | 8 ns to 1 s |
Overshoot | < 1 % |
Jitter (rms) | < 50 ps |
Noise | |
Bandwidth (typical) | 30 MHz |
Arbitrary | |
Frequency | Depending on model |
Model HS5-540 | 0.4 nHz to 30 MHz |
Model HS5-530 | 0.4 nHz to 30 MHz |
Model HS5-220 | 0.4 nHz to 20 MHz |
Model HS5-110 | 0.4 nHz to 10 MHz |
Model HS5-055 | 0.4 nHz to 5 MHz |
Length | |
Standard model | 1 to 256 KiSamples |
XM option | 1 to 64 MiSamples |
Maximum sample rate | Depending on model |
Model HS5-540 | 240 MS/s |
Model HS5-530 | 240 MS/s |
Model HS5-220 | 200 MS/s |
Model HS5-110 | 100 MS/s |
Model HS5-055 | 50 MS/s |
Rise/Fall time | < 8 ns |
Nonlinearity (of peak output) | < 0.01 % |
Settling time | < 8 ns to 10 % final value |
Jitter (RMS) | < 50 ps |
Common characteristics | |
Number of output channels | 1 analog, BNC |
DAC resolution | 14 bit |
Output range | -12 to +12 V (24 Vpp) at open circuit, frequency ≤ 10 MHz -11 to +11 V (22 Vpp) at open circuit, frequency ≤ 20 MHz -9 to +9 V (18 Vpp) at open circuit, frequency ≤ 30 MHz -7.5 to +7.5 V (15 Vpp) at open circuit, frequency ≤ 40 MHz |
Amplitude | |
Ranges | 0.12 V (0.24 Vpp), 1.2 V (2.4 Vpp), 12 V (24 Vpp) at open circuit |
Resolution | 12 bit |
Accuracy | 0.4 % of range |
DC offset | |
Range | -12 to +12 V at open circuit |
Resolution | 12 bit |
Accuracy | 0.4 % of range |
Noise level | |
0.12 V range | 900 µVRMS |
1.2 V range | 1.3 mVRMS |
12 V range | 1.5 mVRMS |
Coupling | DC |
Impedance | 50 Ohm |
Overload protection | Output turns off automatically when overload is applied. Instrument will tolerate a short circuit to ground indefinitely. |
Burst | |
Waveforms | Sine, square, triangle, noise, arbitrary |
Count | 1 to 65535 |
Trigger | Software, external |
Sweep | Available on models with extended memory option XM |
Waveforms | Sine, square, triangle |
Type | Linear, logarithmic |
Direction | Up, down |
Trigger | Software, external |
Modulation | |
AM | |
Carrier waveforms | Sine, square, triangular |
Modulating waveforms | Sine, square, triangular, noise, arbitrary |
Modulating frequency | 2 mHz to 20 MHz |
Depth | 0.0 % to 100 % |
Source | Internal |
FM | |
Carrier waveforms | Sine, square, triangular |
Modulating waveforms | Sine, square, triangular, noise, arbitrary |
Modulating frequency | 2 mHz to 20 MHz |
Peak deviation | DC to 20 MHz |
Source | Internal |
FSK | |
Carrier waveforms | Sine, square, triangular |
Modulating waveforms | 50 % duty cycle square |
Modulating frequency | 2 mHz to 20 MHz |
Peak deviation | 1 µHz to 20 MHz |
Source | Internal |
System characteristics | |
System | Constant Data Size |
Memory | |
Standard model | 256 KiSamples |
Option XM | 64 MiSamples |
Operating modes | Continuous, triggered, gated |
Maximum sampling rate | Depending on model |
Model HS5-530 | 240 MS/s |
Model HS5-220 | 200 MS/s |
Model HS5-110 | 100 MS/s |
Model HS5-055 | 50 MS/s |
Sampling source | Internal TCXO |
Accuracy | ±0.0001 % |
Stability | ±1 ppm over 0°C to +55°C |
Time base aging | ±1 ppm/year |
Multi-instrument synchronization | |
Maximum number of instruments | Limited by number of available USB ports |
Synchronization accuracy | 0 ppm |
Interface | |
Interface | USB 2.0 High Speed (480 Mbit/s); (USB 1.1 Full Speed (12 Mbit/s) and USB 3.0 compatible) |
Power Requirements | |
Power | From USB port or external input |
Consumption | 5 VDC 2000 mA max |
External power | From second USB port or power adapter |
Physical | |
Instrument height | 25 mm (1 inch) |
Instrument length | 170 mm (6.7 inch) |
Instrument width | 140 mm (5.2 inch) |
Weight | 430 g (15 ounce) |
USB cord length | 1.8 m (70 inch) |
I/O connectors | |
Channel 1, 2 | BNC |
Generator | BNC |
USB | Fixed cable with USB 2.0 and USB 1.1 type A connector, 1.8 m |
Extension connector | D-sub 9 pins female |
Power | 3.5 mm power socket |
Auxiliary I/O connectors | 2 x HDMI type C socket |
System requirements | |
PC I/O connection | USB 1.1, USB 2.0 or newer |
Operating system | Windows XP/Vista/7/8/10, 32 and 64 bits Linux (via LibTiePie SDK) |
Environmental conditions | |
Operating | |
Ambient temperature | 0 to 55°C |
Relative humidity | 10 % to 90 %, non condensing |
Storage | |
Ambient temperature | -20 to 70°C |
Relative humidity | 5 % to 95 %, non condensing |
Certifications and Compliances | |
CE mark compliance | Yes |
RoHS | Yes |
EN 55011:2009/A1:2010 | Yes |
EN 55022:2006/A1:2007 | Yes |
EN 61000-6-1:2007 | Yes |
EN 61000-6-3:2007 | Yes |
Package contents | |
Instrument | Handyscope HS5 |
Oscilloscope probes | 2 x Oscilloscope Probe 1:1-1:10 - HP-9250 |
Accessories | Handyscope power supply, external power cable for USB port |
Software | for Windows 2000/XP/Vista/7/8/10 on CD |
Drivers | for Windows 2000/XP/Vista/7/8/10 on CD |
Manuals | instrument manual and software user's manuals color printed and digital on CD |
Customer service | |
TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for three years. | |
This warranty includes | All parts and labor (excluding probes) No charge for return shipping Long-term 7 year support Upgrade to the latest software at no charge |
Optionally available | Extension to five year warranty |